Science and Research

Evaluating Perfusion Quantification for Phase-Resolved Functional Lung MRI Using Gaussian Filtering

Phase-resolved functional lung (PREFUL) MRI enables contrast-free lung perfusion quantification (Q(Quant)). Current quantification uses a single median value per slice of maximal blood exchange fraction (DeltaS), which limits regional assessment, whereas regional DeltaS causes artifacts. This retrospective study aims to optimize Q(Quant) by applying Gaussian filtering to DeltaS to improve intrascan/interscan repeatability in healthy volunteers, while evaluating whether the optimized Q(Quant) retains agreement with dynamic contrast-enhanced (DCE) MRI in chronic obstructive pulmonary disease (COPD) and chronic thromboembolic pulmonary hypertension (CTEPH) patients and exhibits a physiologically plausible gravity-dependent perfusion gradient. Analysis was performed on 29 healthy subjects (11 female, age: 19-33 years), 20 COPD patients (three female, age: 46-76 years) and 15 CTEPH patients (six female, age: 44-82 years), scanned at 1.5 T. Healthy subjects underwent four PREFUL scans in two sessions. Patients just underwent one PREFUL and DCE scan. Q(Quant) maps were calculated while applying different Gaussian filter options to DeltaS. In patients, PREFUL-derived Q(Quant) maps were coregistered to DCE-derived pulmonary blood flow (PBF) maps for global and voxel-wise correlations. In healthy subjects, the gravity-dependent perfusion gradient was quantified by linear regression of slice-wise Q(Quant) across five coronal slices. Gaussian filtering DeltaS with sigma = 1.5 improved intrascan and interscan repeatability in healthy subjects (mean bias: /= 3.75 mL/100 mL; Cohen's d: 0.68). Correlations with PBF remained stable after filtering (sigma = 1.5) in COPD (filtered vs. default DeltaS: global r = 0.57 vs. r = 0.59, voxel-wise r = 0.32 vs. r = 0.32) and CTEPH (global r = 0.32 vs. r = 0.28, voxel-wise r = 0.40 vs. r = 0.41), all significant except global CTEPH. The filtered Q(Quant) maps showed a significant gravity-dependent perfusion gradient (DeltaS filtered sigma = 1.5) of 1.47 mL/min/100 mL/cm. Gaussian filtering DeltaS with sigma = 1.5 improved Q(Quant) repeatability while preserving DCE-MRI agreement and is therefore recommended. The observed gravity-dependent perfusion gradient confirms physiological plausibility, supporting potential in clinical use.

  • Schmidt, K. J.
  • Voskrebenzev, A.
  • Glandorf, J. M. W.
  • Klein, M. M.
  • Behrendt, L.
  • Wacker, F.
  • Vogel-Claussen, J.
  • Klimes, F.

Keywords

  • Humans
  • Female
  • Middle Aged
  • Aged
  • Adult
  • *Lung/diagnostic imaging
  • Normal Distribution
  • Male
  • Aged, 80 and over
  • *Magnetic Resonance Imaging
  • Reproducibility of Results
  • Pulmonary Disease, Chronic Obstructive/diagnostic imaging/physiopathology
  • Young Adult
  • Perfusion Magnetic Resonance Imaging
  • *Perfusion
  • Dce-mri
  • Preful mri
  • perfusion
  • pulmonary MRI
  • repeatability
  • validation
Publication details
DOI: 10.1002/nbm.70420
Journal: NMR Biomed
Pages: e70420 
Number: 11
Work Type: Original
Location: BREATH
Disease Area: PLI
Partner / Member: MHH
Access-Number: 42865264
See publication on PubMed


chevron-down