Acinar micromechanics in health and lung injury: what we have learned from quantitative morphology

Within the pulmonary acini ventilation and blood perfusion are brought together on a huge surface area separated by a very thin blood-gas barrier of tissue components to allow efficient gas exchange. During ventilation pulmonary acini are cyclically subjected to deformations which become manifest in changes of the dimensions of both alveolar and ductal airspaces as well as the interalveolar septa, composed of a dense capillary network and the delicate tissue layer forming the blood-gas barrier. These ventilation-related changes are referred to as micromechanics. In lung diseases, abnormalities in acinar micromechanics can be linked with injurious stresses and strains acting on the blood-gas barrier. The mechanisms by which interalveolar septa and the blood-gas barrier adapt to an increase in alveolar volume have been suggested to include unfolding, stretching, or changes in shape other than stretching and unfolding. Folding results in the formation of pleats in which alveolar epithelium is not exposed to air and parts of the blood-gas barrier are folded on each other. The opening of a collapsed alveolus (recruitment) can be considered as an extreme variant of septal wall unfolding. Alveolar recruitment can be detected with imaging techniques which achieve light microscopic resolution. Unfolding of pleats and stretching of the blood-gas barrier, however, require electron microscopic resolution to identify the basement membrane. While stretching results in an increase of the area of the basement membrane, unfolding of pleats and shape changes do not. Real time visualization of these processes, however, is currently not possible. In this review we provide an overview of septal wall micromechanics with focus on unfolding/folding as well as stretching. At the same time we provide a state-of-the-art design-based stereology methodology to quantify microarchitecture of alveoli and interalveolar septa based on different imaging techniques and design-based stereology.

  • Knudsen, L.
  • Hummel, B.
  • Wrede, C.
  • Zimmermann, R.
  • Perlman, C. E.
  • Smith, B. J.

Keywords

  • Alveolar recruitment
  • electron microscopy
  • imaging
  • interalveolar septa
  • micromechanics
  • pulmonary acinus
  • stereology
Publication details
DOI: 10.3389/fphys.2023.1142221
Journal: Front Physiol
Pages: 1142221 
Work Type: Review
Location: BREATH
Disease Area: PLI
Partner / Member: MHH
Access-Number: 37025383

DZL Engagements

chevron-down