Science and Research

Correction of heat-induced susceptibility changes in respiratory-triggered 2D-PRF-based thermometry for monitoring of magnetic resonance-guided hepatic microwave ablation in a human-like in vivo porcine model

PURPOSE: To develop and evaluate susceptibility corrected 2D proton resonance frequency (PRF)-based magnetic resonance (MR)-thermometry for the accurate assessment of the ablation zone of hepatic microwave ablation (MWA). METHODS AND MATERIALS: Twelve hepatic MWA were performed in five LEWE minipigs with human-like fissure-free liver. Temperature maps during ablation of PRF-based MR-thermometry were corrected by modeling heat induced susceptibility changes. Ablation zones were determined using cumulative equivalent minutes at 43 °C (CEM43) as tissue damage model. T1 weighted (w) post-ablation contrast-enhanced (CE) MR-imaging and manually segmented postmortem histology were used for validation. The agreement of uncorrected (raw) and susceptibility corrected (corr) MR-thermometry with T1w post-ablation CE MR-imaging and histology was evaluated. The Wilcoxon-signed rank test and Bland-Altman analysis were applied. RESULTS: With the susceptibility corrected MR-thermometry a significantly increased dice coefficient (raw: 77% vs. corr: 83%, p < 0.01) and sensitivity (raw: 72% vs. corr: 82%, p < 0.01) was found for the comparison to T1w-CE imaging as well as histopathology (dice coefficients: raw: 76% vs. corr: 79%, p < 0.001; sensitivity: raw: 72% vs. corr: 74%, p < 0.001). While major axis length was significantly increased (7.1 mm, p < 0.001) and minor axis length significantly decreased (2.2 mm, p < 0.001) in uncorrected MR-thermometry compared to T1w-CE MR-imaging, no significant bias was found after susceptibility correction. CONCLUSION: Using susceptibility corrected 2D PRF-based MR-thermometry to predict the ablation zones of hepatic MWA provided a good agreement in comparison to T1w post-ablation CE MR-imaging and histopathology.
  • Hensen, B.
  • Hellms, S.
  • Werlein, C.
  • Jonigk, D.
  • Gronski, P. A.
  • Bruesch, I.
  • Rumpel, R.
  • Wittauer, E. M.
  • Vondran, F. W. R.
  • Parker, D. L.
  • Wacker, F.
  • Gutberlet, M.

Keywords

  • MRI-guided intervention
  • PRF thermometry
  • microwave ablation
  • susceptibility correction
  • thermal ablation
Publication details
DOI: 10.1080/02656736.2022.2138987
Journal: Int J Hyperthermia
Pages: 1387-1396 
Number: 1
Work Type: Original
Location: BREATH
Disease Area: PLI
Partner / Member: MHH
Access-Number: 36336401

DZL Engagements

chevron-down